Trade fairs cancelled. And now? LCTech presents its product news.

close

Artificial Saliva

Fusayama/Mayer Artificial Saliva for Testing of Products for Corrosion, Colorfastness and Discoloration

Used for testing a wide variety of products, incl. dental metal alloys.

pH value 4.9, custom pH
Storage condition refrigerated
Condition ready-to-use solution
Quantity 200 mL

Find your specification:

  Stabilized Not Stabilized
pH 4.9 1700-0309 1700-0301
Custom pH 1700-0306 1700-0307

Artificial Saliva with Mucin

Used for  the evaluation of decontamination procedures for surfaces and materials contaminated with human pathogenic viruses. This artificial saliva can also be used for dental, drug delivery or pharmaceutical studies.

According to ASTM E2720-16 and ASTM E2721-16
Quantity 200 mL
Stabilized Storage at room temperature, ready-to-use solution
Not Stabilized two-part formulation with mucin powder; store refrigerated

Find your specification:

Stabilized Not Stabilized
pH 7 1700-0316 1700-0317
Custom pH 1700-0318 1700-0319

Artificial Saliva for Testing Biodegradability of Dental Metal Alloys

 

According to FNOR NF S91-141
pH value 7.8 after mixing
Storage condition refrigerated
Condition Solution consists of two parts that are mixed right before use.
Quantity 200 mL
Part Number 1700-0302

Artificial Saliva for Testing Colorfastness of Products Intended to Be Taken into the Mouth

 

According to DIN 53160-1:2010-10
pH value 6.8 after mixing
Storage condition frozen
Condition Solution consists of two parts that are mixed right before use.
Quantity 200 mL
Part number 1700-0303

Artificial Saliva for Pharmaceutical Research

Formulated according to literature for pharmaceutical research such as studies of drug dissolution and drug delivery through oral mucosa.

pH value 6.8 (P/N 1700-0304)
Custom pH (P/N 1700-0308)
Storage condition refrigerated
Condition ready-to-use solution
Quantity 200 mL

Artificial Saliva for Medical and Dental Research

Formulated according to literature references for medical and dental research. 
The solution contains Sodium Carboxymethyl Cellulose to increase viscosity of the solution and make it behave similar to natural human saliva.
Only intended for product testing and research, not for medical use.

pH value 6.75
Storage condition room temperature
Shelf life one year
Condition ready-to-use solution, stabilized
Quantity 200 mL
Part number 1700-0305

α-Amylase

Amylase is the main enzyme in human saliva and is needed for starch digestion. As some applications require studying the effect of enzymes in saliva, Pickering Laboratories offers an easy way to add biological activity to your chosen artificial saliva product. Once added to the 200 mL bottle of artificial saliva, our Amylase product will provide 80 U/mL of enzyme activity.
Quantity 16 KU P/N 1700-0320